FaultCodeWiki
Home Appliance (Generator)

GENERAC-1505: Generac Generator Error Code 1505 / 1515 (RPM Sense Loss)

Error code 1505 (or 1515) indicates that the controller lost the RPM signal from the engine magnetos/flywheel while running or cranking. The generator shuts down to prevent engine or alternator damage.

Common Symptoms

Possible Causes

Step-by-Step DIY Fix

  1. Set the generator control switch to OFF and disconnect starter battery power.
  2. Check starter battery voltage with a multimeter (should read at least 12.6V DC at rest); charge or replace if weak.
  3. Inspect the wiring harness connecting the ignition coils / magnetic pickup to the main controller for corrosion or damage.
  4. Clean rust and debris off the magnetic pickup sensor end and flywheel teeth.
  5. Reconnect battery, clear the fault code on the controller, and perform a manual startup test.
Recommended Tool / Replacement Part:
Generac Generator Battery / Ignition Coil
Check Price on Amazon →

← Back to All Error Codes