Home Appliance (Generator)
GENERAC-1505: Generac Generator Error Code 1505 / 1515 (RPM Sense Loss)
Error code 1505 (or 1515) indicates that the controller lost the RPM signal from the engine magnetos/flywheel while running or cranking. The generator shuts down to prevent engine or alternator damage.
Common Symptoms
- Generator starts, runs for a few seconds, and shuts down
- Controller screen displays 'RPM Sense Loss' or Error Code 1505
- Generator cranks repeatedly but fails to stay running
Possible Causes
- Faulty or dirty magnetic pick-up sensor / ignition coils
- Corroded or loose wire harness connectors between ignition coils and control board
- Low battery voltage causing slow cranking speed during start attempt
- Defective controller board
Step-by-Step DIY Fix
- Set the generator control switch to OFF and disconnect starter battery power.
- Check starter battery voltage with a multimeter (should read at least 12.6V DC at rest); charge or replace if weak.
- Inspect the wiring harness connecting the ignition coils / magnetic pickup to the main controller for corrosion or damage.
- Clean rust and debris off the magnetic pickup sensor end and flywheel teeth.
- Reconnect battery, clear the fault code on the controller, and perform a manual startup test.
← Back to All Error Codes